Product Introduction
HY-TSU 6220 Series Audio Isolation Coupling Transformers are designed for EMC testing and can be used as coupling transformers.This series of products are mainly 50A and 100A two models, more needs can consult Hangyu power supply customization, the maximum current can be customized to 2000A.
Application Field
■ Used for EMC testing
■ MIL-STD-704 AC-DC coupling application
■ GJB 572A AC-DC coupling application
■ GJB-181/DO-160 AC-DC coupling application
■ LV123/ISO21498-2/VW80300/VW80303 AC-DC coupling application
Specification
■ Primary induced reactance:<2mH
■ Primary:<5Ω
■ Primary and secondary ratios: 2:1
■ Secondary induced reactance:<1.3mH
■ Secondary: ¼ the primary impedance
■ Secondary saturation: 50 A, AC or DC max.
■ Primary lead mode: Binding post
■ Secondary lead mode: Binding post
■ Voltage detection port: Output 1:1 with primary ratio
■ Dielectric test: DC1000V(primary to secondary), DC3000V insulation (optional)
■ Frequency response: 30 Hz to 250 kHz (less than 5 dB at 30 Hz and less than 14 dB at 250 kHz when primary is loaded with 2 ohms and secondary is loaded with 0.5 ohms)
■ Power: 200W
■ Weight: Approx.8.2kg
■ Size: No terminals159.6(W)*119(D)*139(H)mm
terminals: 209.1(W)*119(D)*139(H)mm